Radio interference suppression filter HLE 310

Radio interference suppression filter HLE 310, HLE 310
Data Standards/Certifications Applications Downloads
General Data
  • Rated voltage 250 Vac
  • Voltage range 0 ‑ 250 Vac
  • Rated current 4 ‑ 55 A
  • Leakage current <3.00 mA
  • Degree of protection IP 20
Advantages

  back to choices show all versions
 
 
  PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet
 
HLE 310-230/4
HLE 310-230/8
HLE 310-230/12
HLE 310-230/16
HLE 310-230/20
HLE 310-230/25
HLE 310-230/30
HLE 310-230/42
HLE 310-230/55
Advantages
Benefits 1
For enhanced requirements
For enhanced requirements
For enhanced requirements
For enhanced requirements
For enhanced requirements
For enhanced requirements
For enhanced requirements
For enhanced requirements
For enhanced requirements
Benefits 2
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Benefits 3
Single-stage filter concept
Single-stage filter concept
Single-stage filter concept
Single-stage filter concept
Single-stage filter concept
Single-stage filter concept
Single-stage filter concept
Single-stage filter concept
Single-stage filter concept
Benefits 4
Efficient filter effect against line-bound interference emissions
Efficient filter effect against line-bound interference emissions
Efficient filter effect against line-bound interference emissions
Efficient filter effect against line-bound interference emissions
Efficient filter effect against line-bound interference emissions
Efficient filter effect against line-bound interference emissions
Efficient filter effect against line-bound interference emissions
Efficient filter effect against line-bound interference emissions
Efficient filter effect against line-bound interference emissions
Benefits 5
Increase in the interference immunity of the connected consumer
Increase in the interference immunity of the connected consumer
Increase in the interference immunity of the connected consumer
Increase in the interference immunity of the connected consumer
Increase in the interference immunity of the connected consumer
Increase in the interference immunity of the connected consumer
Increase in the interference immunity of the connected consumer
Increase in the interference immunity of the connected consumer
Increase in the interference immunity of the connected consumer
Applications
Applications 1
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Operating data
Rated voltage
250 Vac
250 Vac
250 Vac
250 Vac
250 Vac
250 Vac
250 Vac
250 Vac
250 Vac
0 - 250 Vac
0 - 250 Vac
0 - 250 Vac
0 - 250 Vac
0 - 250 Vac
0 - 250 Vac
0 - 250 Vac
0 - 250 Vac
0 - 250 Vac
Rated current
4 A
8 A
12 A
16 A
20 A
25 A
30 A
42 A
55 A
<3.00 mA
<3.00 mA
<3.00 mA
<3.00 mA
<3.00 mA
<3.00 mA
<3.00 mA
<3.00 mA
<3.00 mA
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
Overrating Capacity
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
Standards
Classification
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
Environment
Climatic category
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
Ambient temperature max.
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
Safety and protection
Type
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
Safety class (prepared)
I
I
I
I
I
I
I
I
I
Test voltage
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
Terminal and mounting
Fixing screws
M5
M5
M5
M5
M5
M6
M6
M6
M6
Connections phase/N
Screw clamp, 4 mm²
Screw clamp, 4 mm²
Screw clamp, 4 mm²
Screw clamp, 4 mm²
Screw clamp, 4 mm²
Screw clamp, 10 mm²
Screw clamp, 10 mm²
Screw clamp, 10 mm²
Screw clamp, 16 mm²
Connections PE
Bolt, M5
Bolt, M5
Bolt, M5
Bolt, M5
Bolt, M5
Bolt, M6
Bolt, M6
Bolt, M6
Bolt, M6
Fixing method
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Measures and weights
Weight
0.52 kg
0.58 kg
0.78 kg
0.78 kg
0.80 kg
1.30 kg
1.35 kg
1.45 kg
2.00 kg
  Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture
Notes
*
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Order numbers
Order Number
HLE 310‑230/4
HLE 310‑230/8
HLE 310‑230/12
HLE 310‑230/16
HLE 310‑230/20
HLE 310‑230/25
HLE 310‑230/30
HLE 310‑230/42
HLE 310‑230/55