Low profile transformer FL 14014

Low profile transformer FL 14014, FL 14014
Data Standards/Certifications Applications Downloads
General Data
  • Rated input voltage 2 x 115 Vac
  • Rated output voltage I 9 Vac
  • Rated output voltage II 14.0‑0‑14.0 Vac
  • Rated power 4.34 ‑ 37.3 VA
  • Insulation class E
  • Maximum ambient temperature 40 °C
  • Efficiency up to 78 %
  • Degree of protection IP 00
Advantages
  • Minimum size at high output
  • Low height
  • Double input voltage for series or parallel connection
  • Permanent corrosion protection, high insulation value and maximum electrical reliability thanks to XtraDensiFill resin encapsulation
  • Coil shell in 2‑chamber technology
  • Self‑extinguishing potting material
2 W v

  back to choices show all versions
 
 
  PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet
 
FL 6/14014/9
FL 10/14014/9
FL 14/14014/9
FL 18/14014/9
FL 24/14014/9
FL 30/14014/9
FL 42/14014/9
Input
2 x 115 Vac
2 x 115 Vac
2 x 115 Vac
2 x 115 Vac
2 x 115 Vac
2 x 115 Vac
2 x 115 Vac
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
Output
9 Vac
9 Vac
9 Vac
9 Vac
9 Vac
9 Vac
9 Vac
14.0-0-14.0 Vac
14.0-0-14.0 Vac
14.0-0-14.0 Vac
14.0-0-14.0 Vac
14.0-0-14.0 Vac
14.0-0-14.0 Vac
14.0-0-14.0 Vac
4.34 VA
7.07 VA
10.03 VA
13.19 VA
18.30 VA
26.10 VA
37.30 VA
Rated output current I
0.14 A
0.35 A
0.43 A
0.75 A
1.10 A
1.50 A
1.50 A
Rated output current II
0.11 A
0.14 A
0.22 A
0.23 A
0.30 A
0.45 A
0.85 A
Smoothing Cap. C SEC I
470 µF
1000 µF
1000 µF
2000 µF
4700 µF
4700 µF
4700 µF
Smoothing Cap. C SEC II
2 x 220 µF
2 x 220 µF
2 x 220 µF
2 x 220 µF
2 x 1000 µF
2 x 1000 µF
2 x 1000 µF
No‑load voltage (app. x factor)
1.33
1.32
1.28
1.26
1.22
1.25
1.24
No‑load loss (typ.)
1.20 W
1.20 W
1.40 W
1.40 W
1.80 W
2.20 W
3.80 W
Regulator Reference SEC I
7805
7805
7805
7805
7805
7805
7805
Regulator Reference SEC II
317L,337LZ
317L,337LZ
317L,337LZ
317L,337LZ
317L,337LZ
317L,337LZ
317L,337LZ
Efficiency
68 %
71 %
72 %
74 %
76 %
77 %
78 %
Standards
Classification
Safety isolating transformer
Safety isolating transformer
Safety isolating transformer
Safety isolating transformer
Safety isolating transformer
Safety isolating transformer
Safety isolating transformer
Approvals
Approvals
cURus, ENEC 10 (VDE)
cURus, ENEC 10 (VDE)
cURus, ENEC 10 (VDE)
cURus, ENEC 10 (VDE)
cURus, ENEC 10 (VDE)
cURus, ENEC 10 (VDE)
cURus, ENEC 10 (VDE)
Environment
Ambient temperature max.
40 °C
40 °C
40 °C
40 °C
40 °C
40 °C
40 °C
Safety and protection
Type
encapsulated
encapsulated
encapsulated
encapsulated
encapsulated
encapsulated
encapsulated
Class of Insulation System
VDE=E, UL=class 105
VDE=E, UL=class 105
VDE=E, UL=class 105
VDE=E, UL=class 105
VDE=E, UL=class 105
VDE=E, UL=class 105
VDE=E, UL=class 105
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
Safety class (prepared)
II
II
II
II
II
II
II
Short circuit strength
non-short-circuit proof
non-short-circuit proof
non-short-circuit proof
non-short-circuit proof
non-short-circuit proof
non-short-circuit proof
non-short-circuit proof
Terminal and mounting
Terminals
Pins for printed circuit boards
Pins for printed circuit boards
Pins for printed circuit boards
Pins for printed circuit boards
Pins for printed circuit boards
Pins for printed circuit boards
Pins for printed circuit boards
Measures and weights
Weight
0.18 kg
0.28 kg
0.32 kg
0.38 kg
0.45 kg
0.53 kg
0.72 kg
  Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture
Order numbers
Order Number
FL 6/14014/9
FL 10/14014/9
FL 14/14014/9
FL 18/14014/9
FL 24/14014/9
FL 30/14014/9
FL 42/14014/9