Radio interference suppression filter HFE 104
- Radio interference suppression filter to DIN EN 60939‑2
- Radio interference suppression filter for mains-side interference suppression of power supplies and electronic devices.
| back to choices | show all versions | ||||||
| Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | |
| PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | |
HFE 104-230/1 |
HFE 104-230/2 |
HFE 104-230/3 |
HFE 104-230/6 |
HFE 104-230/10 |
HFE 104-230/16 |
HFE 104-230/20 |
|
| Operating data | |||||||
|---|---|---|---|---|---|---|---|
Rated voltage |
250 Vac
|
250 Vac
|
250 Vac
|
250 Vac
|
250 Vac
|
250 Vac
|
250 Vac
|
|
0 - 250 Vac
|
0 - 250 Vac
|
0 - 250 Vac
|
0 - 250 Vac
|
0 - 250 Vac
|
0 - 250 Vac
|
0 - 250 Vac
|
|
Rated current |
1 A
|
2 A
|
3 A
|
6 A
|
10 A
|
16 A
|
20 A
|
Leakage current (50 Hz) |
0.37 mA
|
0.37 mA
|
0.37 mA
|
0.37 mA
|
0.37 mA
|
0.37 mA
|
0.37 mA
|
|
50 - 60 Hz
|
50 - 60 Hz
|
50 - 60 Hz
|
50 - 60 Hz
|
50 - 60 Hz
|
50 - 60 Hz
|
50 - 60 Hz
|
|
Overrating Capacity |
150 %, shortly
|
150 %, shortly
|
150 %, shortly
|
150 %, shortly
|
150 %, shortly
|
150 %, shortly
|
150 %, shortly
|
| Standards | |||||||
Classification |
EMI filter
|
EMI filter
|
EMI filter
|
EMI filter
|
EMI filter
|
EMI filter
|
EMI filter
|
| Environment | |||||||
Climatic category |
25/085/21
[in accordance with EN 60068-1] |
25/085/21
[in accordance with EN 60068-1] |
25/085/21
[in accordance with EN 60068-1] |
25/085/21
[in accordance with EN 60068-1] |
25/085/21
[in accordance with EN 60068-1] |
25/085/21
[in accordance with EN 60068-1] |
25/085/21
[in accordance with EN 60068-1] |
Ambient temperature max. |
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
| Safety and protection | |||||||
Type |
Metal enclosure
|
Metal enclosure
|
Metal enclosure
|
Metal enclosure
|
Metal enclosure
|
Metal enclosure
|
Metal enclosure
|
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
|
Safety class (prepared) |
I
|
I
|
I
|
I
|
I
|
I
|
I
|
Test voltage |
1700 Vdc Phase/N, 2700 Vdc Phase/PE
|
1700 Vdc Phase/N, 2700 Vdc Phase/PE
|
1700 Vdc Phase/N, 2700 Vdc Phase/PE
|
1700 Vdc Phase/N, 2700 Vdc Phase/PE
|
1700 Vdc Phase/N, 2700 Vdc Phase/PE
|
1700 Vdc Phase/N, 2700 Vdc Phase/PE
|
1700 Vdc Phase/N, 2700 Vdc Phase/PE
|
| Terminal and mounting | |||||||
Connections phase/N |
Tab connector,
6.3 x 0.8 mm |
Tab connector,
6.3 x 0.8 mm |
Tab connector,
6.3 x 0.8 mm |
Tab connector,
6.3 x 0.8 mm |
Tab connector,
6.3 x 0.8 mm |
Tab connector,
6.3 x 0.8 mm |
Tab connector,
6.3 x 0.8 mm |
Connections PE |
Tab connector, 6.3 x 0.8 mm
|
Tab connector, 6.3 x 0.8 mm
|
Tab connector, 6.3 x 0.8 mm
|
Tab connector, 6.3 x 0.8 mm
|
Tab connector, 6.3 x 0.8 mm
|
Tab connector, 6.3 x 0.8 mm
|
Tab connector, 6.3 x 0.8 mm
|
Fixing method |
Mounting lugs
|
Mounting lugs
|
Mounting lugs
|
Mounting lugs
|
Mounting lugs
|
Mounting lugs
|
Mounting lugs
|
| Measures and weights | |||||||
Weight |
0.16 kg
|
0.16 kg
|
0.23 kg
|
0.23 kg
|
0.29 kg
|
0.23 kg
|
0.71 kg
|
| Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | |
| Order numbers | |||||||
Order Number |
HFE 104‑230/1
|
HFE 104‑230/2
|
HFE 104‑230/3
|
HFE 104‑230/6
|
HFE 104‑230/10
|
HFE 104‑230/16
|
HFE 104‑230/20
|