Motor reactor MR3
-
Output reactor for frequency converter
DIN EN 61558‑2‑20, IEC 61558‑2‑20
- Motor reactor for the limitation of the voltage peaks damaging to the motor insulation (du/dt).
ß
W
| back to choices | show all versions | ||||||||||||
MR3 400/2,5 |
MR3 400/4 |
MR3 400/6 |
MR3 400/8 |
MR3 400/10 |
MR3 400/13 |
MR3 400/18 |
MR3 400/24 |
MR3 400/30 |
MR3 400/37 |
MR3 400/42 |
MR3 400/48 |
MR3 400/61 |
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | Buy at distributor | |
| Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | Request to BLOCK | |
| PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | PDF Data sheet | |
| Operating data | |||||||||||||
Rated voltage |
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
3 x 400 Vac
|
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
0 - 3 x 690 Vac
|
|
Rated current |
2.5 A
|
4 A
|
6 A
|
8 A
|
10 A
|
13 A
|
18 A
|
24 A
|
30 A
|
37 A
|
42 A
|
48 A
|
60 A
|
for motor rated output approx. |
0.75 kW
|
1.10 kW
|
2.20 kW
|
3.00 kW
|
4.00 kW
|
5.50 kW
|
7.50 kW
|
11.00 kW
|
15.00 kW
|
18.50 kW
|
22.00 kW
|
22.00 kW
|
30.00 kW
|
Inductivity |
2.550 mH
|
1.590 mH
|
1.060 mH
|
0.800 mH
|
0.640 mH
|
0.490 mH
|
0.350 mH
|
0.270 mH
|
0.210 mH
|
0.170 mH
|
0.150 mH
|
0.130 mH
|
0.100 mH
|
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
0 - 50 Hz
|
|
Switching frequency |
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
3 - 8 kHz
|
| Environment | |||||||||||||
Ambient temperature max. |
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
40 °C
|
| Safety and protection | |||||||||||||
Type |
open type
|
open type
|
open type
|
open type
|
open type
|
open type
|
open type
|
open type
|
open type
|
open type
|
open type
|
open type
|
open type
|
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
IP 00
|
|
Safety class (prepared) |
I
|
I
|
I
|
I
|
I
|
I
|
I
|
I
|
I
|
I
|
I
|
I
|
I
|
Test voltage |
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
4000 Vac, 50 Hz
|
Class of Insulation System |
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
VDE=B, UL=class 130
|
| Terminal and mounting | |||||||||||||
Fixing method |
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing rail
|
Fixing screws |
M4
|
M4
|
M4
|
M4
|
M4
|
M4
|
M4
|
M4
|
M5
|
M5
|
M5
|
M5
|
M6
|
Connections phase/N |
Screw clamp, 4 mm²
|
Screw clamp, 4 mm²
|
Screw clamp, 4 mm²
|
Screw clamp, 4 mm²
|
Screw clamp, 4 mm²
|
Screw clamp, 4 mm²
|
Screw clamp, 4 mm²
|
Screw clamp, 4 mm²
|
Screw clamp, 4 mm²
|
Screw clamp, 4 mm²
|
Screw clamp, 10 mm²
|
Screw clamp, 16 mm²
|
Screw clamp, 16 mm²
|
Connections PE |
Bolt, M4
|
Bolt, M4
|
Bolt, M4
|
Bolt, M4
|
Bolt, M4
|
Bolt, M5
|
Bolt, M5
|
Bolt, M5
|
Bolt, M5
|
Bolt, M5
|
Bolt, M5
|
Bolt, M5
|
Bolt, M6
|
| Measures and weights | |||||||||||||
Weight |
0.70 kg
|
0.75 kg
|
0.90 kg
|
0.95 kg
|
1.70 kg
|
1.80 kg
|
2.50 kg
|
2.60 kg
|
3.50 kg
|
3.60 kg
|
5.20 kg
|
5.80 kg
|
7.40 kg
|
| Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | Dimension Picture | |
| Order numbers | |||||||||||||
Order Number |
MR3 400/2,5
|
MR3 400/4
|
MR3 400/6
|
MR3 400/8
|
MR3 400/10
|
MR3 400/13
|
MR3 400/18
|
MR3 400/24
|
MR3 400/30
|
MR3 400/37
|
MR3 400/42
|
MR3 400/48
|
MR3 400/61
|