Radio interference suppression filter HLD 310

Radio interference suppression filter HLD 310, HLD 310
Data Standards/Certifications Applications Downloads
General Data
  • Rated voltage 3 x 520 Vac
  • Voltage range 0 ‑ 3 x 520 Vac
  • Rated current 3 x 8 ‑ 3 x 250 A
  • Leakage current <0.4 mA
  • Degree of protection IP 20
Advantages
  • For enhanced requirements
  • Low leakage current
  • Single‑stage filter concept
  • Efficient filter effect against line‑bound interference emissions
  • Increase in the interference immunity of the connected consumer
W

  back to choices show all versions
 
 
  PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet
 
HLD 310-500/8
HLD 310-500/12
HLD 310-500/16
HLD 310-500/30
HLD 310-500/42
HLD 310-500/55
HLD 310-500/75
HLD 310-500/100
HLD 310-500/130
HLD 310-500/180
HLD 310-500/250
Operating data
Rated voltage
3 x 520 Vac
3 x 520 Vac
3 x 520 Vac
3 x 520 Vac
3 x 520 Vac
3 x 520 Vac
3 x 520 Vac
3 x 520 Vac
3 x 520 Vac
3 x 520 Vac
3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
0 - 3 x 520 Vac
Rated current
3 x 8 A
3 x 12 A
3 x 16 A
3 x 30 A
3 x 42 A
3 x 55 A
3 x 75 A
3 x 100 A
3 x 130 A
3 x 180 A
3 x 250 A
<0.40 mA
<0.40 mA
<0.40 mA
<0.40 mA
<0.40 mA
<0.40 mA
<0.40 mA
<0.40 mA
<0.40 mA
<0.40 mA
<0.40 mA
Leakage current (50 Hz)**
<3.50 mA
<3.50 mA
<3.50 mA
<3.50 mA
<3.50 mA
<3.50 mA
<3.50 mA
<3.50 mA
<3.50 mA
<3.50 mA
<3.50 mA
Power loss
6.0 W
9.0 W
12.0 W
15.0 W
22.0 W
30.0 W
35.0 W
60.0 W
90.0 W
150.0 W
180.0 W
Overrating Capacity
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
150 %, shortly
Input
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
Standards
Classification
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
EMI filter
Approvals
Approvals
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
cURus, UL 1283 5th edition, CSA 22.2 No.8
Environment
Climatic category
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
25/085/21
[in accordance with EN 60068-1]
Ambient temperature max.
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
50 °C
Safety and protection
SCCR***
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
Type
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
Safety class (prepared)
I
I
I
I
I
I
I
I
I
I
I
Test voltage
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
Terminal and mounting
Connections phase/N
Screw clamp, 4 mm²
Screw clamp, 4 mm²
Screw clamp, 4 mm²
Screw clamp, 10 mm²
Screw clamp, 10 mm²
Screw clamp, 16 mm²
Screw clamp, 35 mm²
Screw clamp, 50 mm²
Screw clamp, 50 mm²
Screw clamp, 95 mm²
Screw clamp, 150 mm²
Connections PE
Bolt, M5
Bolt, M5
Bolt, M5
Bolt, M5
Bolt, M6
Bolt, M6
Bolt, M8
Bolt, M10
Bolt, M10
Bolt, M10
Bolt, M10
Fixing method
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Fixing screws
M5
M5
M5
M5
M5
M5
M6
M6
M6
M6
M6
Measures and weights
Weight
0.78 kg
1.20 kg
1.20 kg
1.80 kg
2.10 kg
2.50 kg
4.50 kg
5.20 kg
5.60 kg
9.20 kg
12.20 kg
  Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture
Notes
*
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
**
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
***
with corresponding preliminary fuse
with corresponding preliminary fuse
with corresponding preliminary fuse
with corresponding preliminary fuse
with corresponding preliminary fuse
with corresponding preliminary fuse
with corresponding preliminary fuse
with corresponding preliminary fuse
with corresponding preliminary fuse
with corresponding preliminary fuse
with corresponding preliminary fuse
Order numbers
Order Number
HLD 310‑500/8
HLD 310‑500/12
HLD 310‑500/16
HLD 310‑500/30
HLD 310‑500/42
HLD 310‑500/55
HLD 310‑500/75
HLD 310‑500/100
HLD 310‑500/130
HLD 310‑500/180
HLD 310‑500/250