All‑pole sinusoidal filter SFA 400

All‑pole sinusoidal filter SFA 400, SFA 400
Data Standards/Certifications Applications Downloads
General Data
  • Rated voltage 3 x 400 Vac
  • Rated current 1.3 ‑ 60 A
  • for motor rated output 1.5 ‑ 30 kW
  • for clock frequencies ≥8 kHz
  • Rated frequency from 0 to 60 Hz
  • Insulation class H
  • Maximum ambient temperature 40 °C
  • Degree of protection IP 20
Advantages
  • Prevention of overvoltages on the motor
  • Long cable lengths possible
  • Reduction in motor noise
  • Minimize of bearing currents
  • Minimize of in leakage currents (is beneficial in the event of incorrect RCD tripping)
  • Reduction in line‑borne and field‑borne emitted interference: can be omitted from shielded cables, where necessary
  • Reduction in motor losses
ß W

  back to choices show all versions
 
 
  PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet
 
SFA 400/1,3
SFA 400/2,5
SFA 400/4
SFA 400/6
SFA 400/10
SFA 400/16,5
SFA 400/24
SFA 400/32
SFA 400/40
SFA 400/50
SFA 400/60
Operating data
Rated voltage
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
3 x 380 - 3 x 480 Vac
Voltage drop
<5%
<5%
<5%
<5%
<5%
<5%
<5%
<5%
<5%
<5%
<5%
Rated current
1.3 A
2.5 A
4 A
6 A
10 A
16.5 A
24 A
32 A
40 A
50 A
60 A
for motor rated output approx.
0.55 kW
1.10 kW
1.50 kW
2.20 kW
4.00 kW
7.50 kW
11.00 kW
1500.00 kW
18.50 kW
22.00 kW
30.00 kW
≤60 Hz
≤60 Hz
≤60 Hz
≤60 Hz
≤60 Hz
≤60 Hz
≤60 Hz
≤60 Hz
≤60 Hz
≤60 Hz
≤60 Hz
Switching frequency
≥8 kHz
≥8 kHz
≥8 kHz
≥8 kHz
≥8 kHz
≥8 kHz
≥8 kHz
≥8 kHz
≥8 kHz
≥8 kHz
≥8 kHz
Approvals
Approvals
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
Environment
Ambient temperature max.
45 °C
45 °C
45 °C
45 °C
45 °C
45 °C
45 °C
45 °C
45 °C
45 °C
45 °C
Safety and protection
Type
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Metal enclosure
Class of Insulation System
F
F
F
F
F
F
F
F
F
F
F
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
Safety class (prepared)
I
I
I
I
I
I
I
I
I
I
I
Test voltage
2500 Vac, 50 Hz
2500 Vac, 50 Hz
2500 Vac, 50 Hz
2500 Vac, 50 Hz
2500 Vac, 50 Hz
2500 Vac, 50 Hz
2500 Vac, 50 Hz
2500 Vac, 50 Hz
2500 Vac, 50 Hz
2500 Vac, 50 Hz
2500 Vac, 50 Hz
Terminal and mounting
Fixing method
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Mounting lugs
Fixing screws
M5
M5
M5
M5
M6
M6
M6
M6
M6
M6
M6
Connections phase/N
Screw clamp, 4 mm²
Screw clamp, 4 mm²
Screw clamp, 4 mm²
Screw clamp, 10 mm²
Screw clamp, 10 mm²
Screw clamp, 10 mm²
Screw clamp, 16 mm²
Screw clamp, 16 mm²
Screw clamp, 16 mm²
Screw clamp, 16 mm²
Screw clamp, 35 mm²
Connections PE
Bolt, M4
Bolt, M4
Bolt, M4
Bolt, M4
Bolt, M5
Bolt, M5
Bolt, M6
Bolt, M6
Bolt, M6
Bolt, M6
Bolt, M8
Measures and weights
Weight
3.20 kg
4.70 kg
7.40 kg
8.10 kg
11.00 kg
17.00 kg
25.00 kg
27.00 kg
34.00 kg
45.00 kg
56.00 kg
  Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture
Order numbers
Order Number
SFA 400/1,3
SFA 400/2,5
SFA 400/4
SFA 400/6
SFA 400/10
SFA 400/16,5
SFA 400/24
SFA 400/32
SFA 400/40
SFA 400/50
SFA 400/60