General Data
  • Rated voltage 3 x 400 Vac
  • Short‑circuit voltage (uK) 2 %
  • Rated current 3 x 2 ‑ 3 x 63 A
  • Inductivity 0.650 ‑ 6.100 mH
  • Insulation class (IEC) B, H or F
  • Ambient temperature ‑10° C to +40° C
  • Protection index IP 00
  • Multifunctional mounting brackets
Advantages
  • Use as line reactor, commutating reactor or PFC reactor
  • Ensuring the short‑circuit voltage of 2 % to the mains
  • Power harmonic damping
  • Starting current limitation
  • Increases the service life of consumers
  • Low ripple
  • Briding voltage dips
  • Peak current limitation
  • Very good corrosion protection and low noise thanks to BLOCKIMPEX vacuum impregnation
  • Multifunctional fixing rail
ß W

  back to choices show all versions
 
 
  PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet PDF Data sheet
 
ALR3 40-2/2
ALR3 40-2/4
ALR3 40-2/6
ALR3 40-2/8
ALR3 40-2/10
ALR3 40-2/16
ALR3 40-2/20
ALR3 40-2/25
ALR3 40-2/30
ALR3 40-2/35
ALR3 40-2/40
ALR3 40-2/45
ALR3 40-2/50
ALR3 40-2/63
Operating data
Rated voltage
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
3 x 400 Vac
Rated voltage (IEC)
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
3 x 690 Vac
Rated voltage (UL)
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
3 x 600 Vac
Short circuit voltage uK
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
2.0 %
Voltage drop
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
4.6 Vac
Rated current
2 A
4 A
2 A
8 A
10 A
16 A
20 A
25 A
30 A
35 A
40 A
45 A
50 A
63 A
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
50 - 60 Hz
Inductivity
6.100 mH
3.050 mH
6.100 mH
1.530 mH
1.220 mH
0.760 mH
0.610 mH
0.490 mH
0.410 mH
0.350 mH
0.310 mH
0.270 mH
0.240 mH
0.190 mH
Inductivity deviation
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
Approvals
Approvals
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
cURus
Environment
Ambient temperature
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
-10° C to +40° C
Cooling method
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
Safety and protection
Type
open type
open type
open type
open type
open type
open type
open type
open type
open type
open type
open type
open type
open type
open type
Class of Insulation System
IEC=B, UL=class 130
IEC=B, UL=class 130
IEC=B, UL=class 130
IEC=B, UL=class 130
IEC=B, UL=class 130
IEC=F, UL=class 155
IEC=F, UL=class 155
IEC=F, UL=class 155
IEC=F, UL=class 155
IEC=F, UL=class 155
IEC=F, UL=class 155
IEC=H, UL=class 180
IEC=H, UL=class 180
IEC=H, UL=class 180
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
IP 00
Safety class (prepared)
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Test voltage
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
4000 Vac
Terminal and mounting
Connections phase/N
Europe terminal, 2.5 mm²
Europe terminal, 2.5 mm²
Europe terminal, 2.5 mm²
Europe terminal, 6 mm²
Europe terminal, 6 mm²
Europe terminal, 6 mm²
Europe terminal, 6 mm²
Europe terminal, 6 mm²
Europe terminal, 10 mm²
Europe terminal, 10 mm²
Europe terminal, 10 mm²
Europe terminal, 10 mm²
Europe terminal, 16 mm²
Europe terminal, 16 mm²
Connections PE
for M5
for M5
for M5
for M5
for M5
for M5
for M5
for M5
for M5
for M5
for M5
for M5
for M5
for M5
Fixing method
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Mounting brackets
Fixing screws
M6
M6
M6
M6
M6
M6
M6
M6
M6
M6
M6
M6
M6
M6
Measures and weights
Weight
0.53 kg
0.53 kg
0.53 kg
1.30 kg
1.50 kg
2.00 kg
2.00 kg
2.90 kg
2.90 kg
2.90 kg
3.80 kg
3.80 kg
5.80 kg
6.80 kg
  Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture Dimension Picture
Order numbers
Order Number
ALR3 40‑2/2
ALR3 40‑2/4
ALR3 40‑2/6
ALR3 40‑2/8
ALR3 40‑2/10
ALR3 40‑2/16
ALR3 40‑2/20
ALR3 40‑2/25
ALR3 40‑2/30
ALR3 40‑2/35
ALR3 40‑2/40
ALR3 40‑2/45
ALR3 40‑2/50
ALR3 40‑2/63