EMC-Filter/Reactors
501 from 501 Products
-
NKE
Ă
W
Line reactor, single phase
single phase, 2 ‑ 25 A
12 from 12 versions
-
LR3
Ă
W
Line Reactor, three phase
three phase, 3 x 2 ‑ 3 x 1600 A
102 from 102 versions
-
LR3A
Ă
W
Line Reactor, three phase, aluminium
three phase, 3 x 2 ‑ 3 x 1600 A
54 from 54 versions
-
ALR3
Ă
W
Line Reactor, three phase, 2 % (uK)
three phase, 3 x 2 ‑ 3 x 63 A
14 from 14 versions
-
NKD
Ă
W
Line reactor, three phase, 4 % (uK)
three phase, 3 x 2 ‑ 3 x 200 A
16 from 16 versions
-
FKD
Ă
Harmonic circuit filter reactor
7 ‑ 14 % filtering factor, 25 ‑ 50 kvar
8 from 8 versions
-
HF1K
Ă
W
Harmonic Filter
for generating sinusoidal supply currents, reduction of the harmonic levels to THD‑I ≤16 %, 10 ‑ 433 A
8 from 8 versions
-
HFM‑FB
Ă
W
Harmonic Filter
for generating sinusoidal supply currents, reduction of the harmonic levels to THD‑I ≤5 %, 10 ‑ 433 A
27 from 27 versions
-
HFE 156
Radio interference suppression filter, single phase
for generalized requirements, panel installation on mounting rail, single phase 1 ‑ 16 A
6 from 6 versions
-
HFE 356
Radio interference suppression filter,
single phase, low leakage current
for generalized requirements, low leakage current, panel installation on mounting rail, single phase, 3 ‑ 16 A
6 from 6 versions
-
HFE 104
Radio interference filter, single phase, low leakage current
for electronic and electric applications, single phase, 1 ‑ 20 A
7 from 7 versions
-
HFE 200
Radio interference suppression filter, single phase, low leakage current
for increased requirements, leakage current, two stage filter concept, single phase, 1 ‑ 16 A
6 from 6 versions
-
HLE 110
Radio interference suppression filter, single phase
for converter applications and installation engineering, three phase 3 x 8 ‑ 3 x 250 A
9 from 9 versions
-
HLE 310
Radio interference filter, single phase, low leakage current
for converter applications and installation engineering, three phase 4 ‑ 55 A
9 from 9 versions
-
HLE 810
Radio interference filter, single phase, no leakage current
for converter applications and installation engineering, three phase 3 x 8 ‑ 3 x 250 A
9 from 9 versions
-
HFD 156
Radio interference suppression filter, three phase
for generalized requirements, panel installation on mounting rail, three phase 3 x 3 ‑ 3 x 16 A
5 from 5 versions
-
HFD 356
Radio interference suppression filter, three phase, low leakage current
for generalized requirements, low leakage current, panel installation on mounting rail, three phase, 3 x 3 ‑ 3 x 16 A
5 from 5 versions
-
HLD 103
Radio interference suppression filter, three phase
5 from 5 versions
-
HLD 110
W
Radio interference suppression filter, three phase
for inverter applications and plant engineering, three phase, 3 x 8 ‑ 3 x 250 A
11 from 11 versions
-
HLD 310
W
Radio interference suppression filter, three phase, low leakage current
for inverter applications and plant engineering, three phase, 3 x 8 ‑ 3 x 250 A
11 from 11 versions
-
HLD 710
W
Radio interference suppression filter, three phase, low leakage current
for inverter applications and plant engineering, three phase, 3 x 8 ‑ 3 x 250 A
11 from 11 versions
-
HLD 810
W
Radio interference suppression filter, three phase, for IT Network
for inverter applications and plant engineering, three phase, 3 x 8 ‑ 3 x 250 A
11 from 11 versions
-
HFD 500
Radio interference suppression filter, three phase
for generalized requirements, three phase, 3 x 8 ‑ 3 x 110 A
7 from 7 versions
-
HFD 210
U
Radio interference filter, three phase
for increased requirements, two stage filter concept, three phase, 3 x 7 ‑ 3 x 180 A
9 from 9 versions
-
HFD 510
Radio interference filter, three phase
for highest requirements, two stage filter concept, 3 x 8 ‑ 3 x 180 A
8 from 8 versions
-
HFD 503
Radio interference suppression filter,
three phase with energy recovery
for high current applications of automation, enineering, multi stage, three phase 3 x 250 ‑ 3 x 1200 A
9 from 9 versions
-
HLV 110
Radio interference suppression filter,
three phase with neutral conductor
for inverter applications and plant engineering, three phase + neutral conductor, 4 x 8 ‑ 4 x 250 A
11 from 11 versions
-
HLV 310
Radio interference suppression filter,
three phase with neutral conductor, low leakage current
for inverter applications and plant engineering, three phase, 3 x 8 ‑ 3 x 250 A
11 from 11 versions
-
HLV 710
Radio interference suppression filter,
three phase with neutral conductor, low leakage current
for inverter appiolicatns and plant engineering, three phase, 3 x 8 ‑ 3 x 250 A
11 from 11 versions
-
HLV 810
Radio interference suppression filter, three phase with neutral conductor, no leakage current
for converter applications and installation engineering, three phase 3 x 8 ‑ 3 x 250 A
11 from 11 versions
-
HFV 510
Radio interference suppression filter,
three phase with neutral conductor
for highest requirements, two stage filter concept, three phase + neutral conductor, 4 x 16 ‑ 4 x 80 A
8 from 8 versions
-
KH 250
Magnetic voltage stabilizer
enclosed, encapsulated, 250 VA
1 from 1 versions
-
BSD
Magnetic voltage stabilizer
enclosed, 60‑3000 VA
9 from 9 versions
-
SFB
Ă
W
Sinusoidal filter
sinusoidal output signal, switching frequency range from 3 ‑ 8 kHz, 3 x 4 A ‑ 3 x 440 A
16 from 16 versions
-
SFA 400
Ă
W
All‑pole sinusoidal filter
for converter applications and installation engineering, three phase 3 x 1,3 ‑ 3 x 60 A
11 from 11 versions
-
MDB
Ă
Motor reactor
du/dt limitation, for 2 ‑ 6 kHz switching frequencies, no converter overload, 3 x 6.3 ‑ 3 x 176 A
14 from 14 versions
-
MR3
Ă
W
Motor reactor
du/dt limitation, for 3 ‑ 8 kHz switching frequencies, no converter overload, 3 x 2.5 ‑ 3 x 61,0 A
13 from 13 versions