Starting current limiter, current measurement included ESG 3 / ESG 4 / ESG 5
- Starting current limiting option for limiting the starting current in power tools, transformers and other consumers with high switch-on or starting currents.
| back to choices | show all versions | |||
ESG 3 |
ESG 4 |
ESG 5 |
||
|---|---|---|---|---|
| Request to BLOCK | Request to BLOCK | Request to BLOCK | ||
| PDF Data sheet | PDF Data sheet | PDF Data sheet | ||
| Operating data | ||||
Rated voltage |
110 - 230 Vac ±10 %
|
110 - 230 Vac ±10 %
|
110 - 230 Vac ±10 %
|
|
Voltage range |
99 - 253 Vac
|
99 - 253 Vac
|
99 - 253 Vac
|
|
Rated frequency |
50 - 60 Hz
|
50 - 60 Hz
|
50 - 60 Hz
|
|
Rated current |
max. 16 A
|
max. 16 A
|
max. 16 A
|
|
| Environment | ||||
Ambient temperature max. |
40 °C
|
40 °C
|
40 °C
|
|
| Safety and protection | ||||
Type |
Resin encapsulated transformer
|
Resin encapsulated transformer
|
Resin encapsulated transformer
|
|
Protection index |
housing IP 65, housing connections IP 44
|
housing IP 65, housing connections IP 20
|
housing IP 65, housing connections IP 20
|
|
Safety class (prepared) |
I
|
I
|
I
|
|
Internal impedance |
7.80 Ω
|
7.80 Ω
|
4.40 Ω
|
|
| Terminal and mounting | ||||
Terminals PRI |
Connecting cable with DIN49440,1 protected contact plug (GER)
|
Connecting cable with BS 1663 protected contact plug (UK)
|
Connecting cable with NEMA5‑15 protected contact plug (USA)
|
|
Terminals SEC |
Cconnecting cable with DIN49440,1 protected contact coupling (GER)
|
Connecting cable with BS 1663 protected contact coupling (UK)
|
Connecting cable with NEMA5‑15 protected contact coupling (USA)
|
|
| Measures and weights | ||||
Weight |
0.69 kg
|
0.69 kg
|
0.69 kg
|
|
Dimensions W x H x D |
66 x 70 x 121 mm
|
66 x 70 x 121 mm
|
66 x 70 x 121 mm
|
|
Dimension picture on request |
Dimension picture on request |
Dimension picture on request |
||
| Order numbers | ||||
Order Number |
ESG 3
|
ESG 4
|
ESG 5
|
|